What new in build 4.16.0.401 (10/04/07) - Bug fixed: 0xfe10 error code under scheduled record What new in build 4.16.0.400 (09/04/07) - Some updates for help file What new in build 4.16.0.400 (08/04/07) - Audio resampler for TV tuners that produce only 32kHz audio. - mux_dat.bin file now located into the "..application data/iulabs/iuvcr" folder - some other minor improvements and fixes. What new in build 4.15.0.379 (24/12/06) - Support for "dump" writer added. - iuLab Mirror improved. What new in build 4.14.1.378 (26/11/06) - Changes into the preset loading procedure for audio device. What new in build 4.14.0.377 (27/09/06) - Fixed old stupid bug of audio crossbar routing. What new in build 4.13.0.376 (19/09/06) - A small audio level indicator on the "info" tab. - Record indication an the preview window caption. - New filter: iuLab Mirror. What new in build 4.12.0.375 (24/08/06) - "Remember password" option for scheduler. - New filter: FieldShift for horizontal field shifting. What new in build 4.11.0.374 (05/07/06) - Bug Fixed: The "/P:" command line switch crashes iuVCR if symbolic preset name was specified. What new in build 4.11.0.373 (04/07/06) - Wav Dest muxer to record wav files. - Suspend mode appended for scheduled tasks. - 'Delete the task when it is done' option for scheduler dialog. - Changes for mux_guids.dat importing algorithm. What new in build 4.10.0.372 (01/14/06) - New filter 'iuLab Fill borders' What new in build 4.10.0.371 (12/23/05) - Bug Fixed: Too many skiped frames. What new in build 4.10.0.370 (12/20/05) - Significant improvement of A/V synchronization in AVI files. - Audio samples always short now (related option hidden). What new in build 4.9.4.369 (11/19/05) - New option 'Force render' on the audio tab. - Some fixes for crossbar control. What new in build 4.9.4.367 (08/10/05) - Bug fixed: superfluous "i" symbol into the scheduler command line. - Additional support for VH Screen Capture Driver. What new in build 4.9.4.366 (05/08/05) - Bug fixed: Access violation when built in capture chip audio source selected. What new in build 4.9.4.365 (04/24/05) - Bug fixed: Second instance of iuVCR can not close previous instance. - Bug fixed: Wrong command line may be created into the scheduler dialog. What new in build 4.9.4.364 (04/17/05) - Any custom muxer may store settings into the iuVCR profile. What new in build 4.9.4.362 - Bug fixed: under Pinnacle DC10 preview is absent during record. What new in build 4.9.4.361 - Some fixes for preview window. What new in build 4.9.4.360 - Bug fixed: Wrong picture size in full screen mode. - Some improvements for preview window. - Diagnostic message if system scheduler unavailable. What new in build 4.9.4.357 - Some improvements for preview window. - Bug fixed: Error during installation. - Bug fixed: Scheduled record cannot start. What new in build 4.9.3.355 - "Asf" default extension forced when "Direct ASF writer" muxer by Vladimir Filippov selected. - The motion detecror filter has been updated. - Bug fixed: Fullscreen mode breaks desktop layout. - Bug fixed: CAPITAL letters for output file name for scheduled records. What new in build 4.9.2.354 - Bug fixed: PCI streamed audio is absent at preview mode. - Some internal improvements into the frame format dialog. - Some improvements to exclude windows taskbar area for full screen preview. What new in build 4.9.1.351 - Several minor bug fixes - Handler to new segment switch implemented. What new in build 4.9.1.350 - Bug fixed: Access Violation for devices without crossbar. - Minor improvements into the service filter. What new in build 4.9.1.349 - Bug fixed: zero-length file for some options combination. - Own algorithms to search crossbar and tv-tuner filters. What new in build 4.9.0.348 - More safe procedure for crossbar searching. - Bug fixed: Missing item into the tv standards list. - More correct audio format assigment. - New filter: iuLab Decimate. - New option to disable switch channels by mouse scroller. What new in build 4.9.0.346 - Bug fixed: Own mux did not work into the build 4.9.0.345. - Bug fixed: Wrong file size into the statistic for Matroska Muxer. - Own muxer has options now. - Timer button moved to main panel. - "Apply setting to each channel" function implemented. - "Copy log to clipboard" function implemented. - More comfortable controls for log functions. - Several new messages into the log file. What new in build 4.9.0.345 - Bug fixed: mapped channels have zero values for brightness, contrast, etc - Inputs mapping performs now during first programm launch only. - Support for third party muxers implemented. - Matroska muxer (http://www.matroska.org) supported if this filter present into a system. What new in build 4.8.10.343 - Automatic mapping to channels for SVideo and Composite inputs. - Indicator for recording level. What new in build 4.8.9.342 - New filter included: ECPSoft ImagePlus filter allows insert own logo. What new in build 4.8.8.341 - New iuLab Field Swap filter included. - A recording mixer line now restores after iuVCR shutdown. - Bug fixed: Display go to the power saving mode during active preview. - Bug fixed: Wrong processing for legacy /ch switch into the scheduler. - The "Force channel index" option removed from the scheduler. What new in build 4.8.7.340 - Bug fixed: Error during filter addition if Windows Movie Maker 2 present into the system. What new in build 4.8.7.339 - Each channel has an unique Id now to prevent confusion after channel re-sorting. - Drop-down list with channels inserted to the scheduled session dialog. - Bug fixed: Video device Id does not store into the registry if first device selected. - New iuLab Motion Detector filter included. - New iuLab Deinterlace filter included. - The iuLab Timestamp filter improved. - Some changes into the filter insertion dialog. - During uninstall procedure iuVCR will asks about removing settings from registry. What new in build 4.8.6.337 - Bug fixed: audio is absent during preview for DV devices. - Bug fixed: at some cases codec selection generate error. - Bug fixed: bad spin edit behavior into the scheduler window. What new in build 4.8.5.335 - Powerfull deinterlace filter by Alparysoft (http://www.alparysoft.com) bundled - Bug fixed: for DV devices codec changing fails during preview active. What new in build 4.8.5.334 - Bug fixed: Preview freezes at some cases. What new in build 4.8.5.333 - Bug fixed: unstable work with DV devices. What new in build 4.8.5.331 - Filters list sorted now. - Some changes into filters chain building procedure to improve stability. - Channels stored also if tuner module is absent. What new in build 4.8.4.329 - Bug fixed: noise during channels switching. What new in build 4.8.4.328 - Bug fixed: EAccessVilolation error during iuVCR start if "don't record audio" item selected. - Bug fixed: Two memory leaks. What new in build 4.8.4.327 - Support for several tuner inputs if are provided by driver. - Some changes into the "channels" tab GUI. - brightness/contrast/hue/saturation now always forced before record starts. - Bug fixed: Some sample rates are not available (was broken in 4.8.3.321). What new in build 4.8.3.321 - Support for audio out pins provided by video source filter. - Improved compatibility with SAA713x-based cards. - Improved presets tab. - Each channel can remember specific crossbar settings now. - Some changes into the switch to Full Screen mode routine. - Limited FM radio support (playback only). - Bug Fixed: Mouse weel do switch a channels when codecs combobox is open. - Bug Fixed: Wrong statistic at the "info" tab when "pause" button used. - Bug Fixed: The paused state don't reset after stop session when pause active. What new in build 4.8.2.314 - Bug Fixed: Under scheduled session iuVCR stop but not close when signal vanish. - Stop timer implemented. Call pop-up menu for "Stop record" button to activate. - Some changes for GUI. - Some changes for stream service filter. What new in build 4.8.1.312 - Bug Fixed: wrong UYVY->RGB24 color conversion for screenshot What new in build 4.8.1.309 - Checkbox "Wake the computer to run this session" implemented into the scheduler dialog - New graphics for some GUI elements. - Bug Fixed: empty main window after iuVCR run in "Minimized" state. What new in build 4.8.0.295 - Bug Fixed: Incorrect WM_QUERYENDSESSION message processing. - Windows animation effects removed. What new in build 4.8.0.294 - New streams synchronization algorithm implemented into the own MUX/writer filter. - The "iuLab Timestamp" filter have several options now What new in build 4.7.4.293 - New filter "iuLab Timestamp" - New option "Allow DV transport control" for DV devices - Little changes and fixes for interface What new in build 4.7.4.291 - Bug Fixed: No sound when capturing to DV format from analog video source does perform. What new in build 4.7.4.290 - Bug Fixed: preview position does restore improper sometimes What new in build 4.7.3.288 - Bug fixed: Broken hibernation routine. - End time instead duration can be specified at the Scheduler dialog. - New version of experimental MUX/file writer included What new in build 4.7.2.285 - Fixed broken statistic calculation for DV devices. What new in build 4.7.1.283 - Fixed ugly GUI under large desktop fonts. What new in build 4.7.0.282 - The "Enable Preview" button have a little pop-up menu now. - Preview windows moving algorithm changed. - Some changes for crossbar inputs enumeration. - DV devices detection procedure improved, - A frame rate calculated more accuracy now. - Fixed errors with manipulations for preview window under DC10+ cards. What new in build 4.6.0.271 - New experimental MUX/file writer which allows to write segments without a gaps. What new in build 4.5.0.268 - Some fixes for Pinnacle Miro DC10+ - Fixed memory overrun when vfw codec does state saving. - Some changes into filter enumeration procedure. - The main window can minimize to tray now. - Some stuff for bad vfw devices filtering What new in build 4.4.0.260 - The stream format dialogs must work more correctly now. What new in build 4.3.0.259 - Some fixes for compatibility with Windows 98 system. What new in build 4.2.0.258 - A support for encoding analog video to DV format implemented - New filter named "histogram" included. - Fixed another bug with audio routing in crossbar during channels switch. - Some improvements for onesot mode. - The "Short Audio Samples" option turned off automatically if non-PCM audio format was selected. What new in build 4.1.0.255 - A little memory allocation bug was fixed. - The "Oneshot" recording mode implemented. - Fixed bug with audio routing in crossbar during channels switch. - New option: "Stop when signal vanish". - The algorithm of assigned names for segments changed. What new in build 4.1.0.248 - The iuVCR will prevent putting the computer in the sleeping state now. What new in build 4.1.0.246 beta 4 - Fixed the "green drops at start" bug for Nvidia-based cards - Folders autocreated now if not exist (under Win2000/XP only) - Uninstall icons for iuVCR will not multiply more - Some additional bug fixes What new in build 4.1.0.241 beta 3 - The "Shedule" tab will work under Win98SE now. - Restored a capturing with "smart tee for preview" mode (Was broken in build 4.1.0.238). What new in build 4.1.0.240 beta 2 - A bug of audio format choice was fixed - A correct names of DV devices displays now on the "video" tab. What new in build 4.1.0.238 beta 1 - Support for DV devices implemented. - Presets now stored into system registry with unique device id instead simple index. - The sample grabber filter now unconnected while recording. - Some little bug fixes. - A new command appended to WM_COMMAND API. 04/28/2002 Version 4.0 - Some changes into help file (A many thanks to Steve Gunn for the help) - The preview window may toggle full screen mode by mouse double click - Log file now may be saved automatically when recording done. - Synchronization options were remade again. - An alternative fps/dropped frames detection added 04/08/2002 Version 4.0 RC1 - Updated help included - Errors handling improved - A synchronization options were remade - Recording with timer implemented. - The "Start capture" button having pop-up menu now - Filters Manager improved - The "Snapshot" button having pop-up menu now - Splash during start added - Many bugs fixed 02/27/2002 Version 4.0 beta5 - Still capture implemented - Pause function implemented - Some fixes for wrong mapping of the SVideo input to a channel - Other fixes. 01/21/2002 Version 4.0 beta4 - Hotfix for video codec appending failures. - Stroing and restoring settings for DirectShow video compressors implemented. 01/20/2002 Version 4.0 beta3 - Fixed bug for nvidia wdm drivers: now error blue screen not appear. - Some changes for processing VFW codecs like divx 3.xx - New command line keys: /PWR:Off and /PWR:Hibernate for turn PC off when scheduled session done. - The COM interface is not supported any more. 01/11/2002 Version 4.0 beta2 - TV-tuning was remade. Now several tunning mode can be assigned for each channel. Also mapping Svideo or Composite-In to "fake" channel available. - Scheduling now get new front-end instead standard system schedule dialog. - New command line key: /CHA: for absolute channel number assign - New command line key: /TVI:Cable and /TVI:Antenna for force tuner input selection. - Some minor bug fixes and changes. 12/16/2001 Version 4.0 beta1 - Filter manager implemented. You can use any DirectShow filters as plugins for realtime videostream processing. iuVCR 4 beta 1 include one original filter for image cropping. - Options tab remade. - Special experimental option - the "delay audio stream" for synchronically start video and audio streams was appended. 12/03/2001 Version 3.11 - Workaround added for solve muted recording problem with some wdm drivers. - More correctly processing for the "Mixing renderer" filter existing only into Windows XP. - Bug fixed: "Acces violation" message during capture start without audio stream. 11/15/2001 Version 3.10 - Several fixes for iuVCR work correctly under Windows XP and DirectX 8.1. - Bug fixed: "division by zero" message appear in some cases when capture session start. - Improvements for several identical devices support 10/23/2001 Version 3.9 - The "Max file time" option implemented for files segmentation. - The "One stamp for all session" option added. - Bug fixed: File overwriting when Windows Media Format using. - Now indexing control for Windows Media Format available. You can turn off indexing for prevent of delays during segment switching. - Statistic for Windows Media Format now work properly (require DX8.1 or higher). - Now iuVCR may work more 47 days continuously because the GetTickCount function is not used any more in the statistic routine. - New "Hide title bar" option implemented for preview window. 09/19/2001 Version 3.8 - TVAudio button for calling a standard TVAudio dialog added on the "Video" tab. - Bug fixed: "Stay on top" option don't work properly. - Bug fixed: iuVCR is not switching to capture automatically when /p parameter using into command line. - Several options added. - Now if .AVI file already exists iuVCR always will set new name for overwriting preventing. - The "Max file size" box now accepting any values. 09/08/2001 Version 3.7 - Recording .avi files without audio streams available now. - A second crossbar supporting now for ATI All-In-Wonder like cards. - Bug fixed: several same items are displayed in the video stream configuration dialog at some cases. - Bug fixed: during terminating of the iuVCR in some cases a exception occurs. - Changes in algorithm of numeration segmented files. - The list of video compressors now is displaying a DirectShow-based and VFW-based codecs with different colors and prefixes. - Some cosmetic changes on the 'Info" tab. 08/27/2001 Version 3.6 - Settings for web cameras now also remember into presets. - New command line switch: /dev:. - Channels scan algorithm improved for TV-tuners without indication of PLL offset. - Bug fixed: the "access violation" trap when the "channels scan params" dialog cancel and switching to any channel performed. 08/16/2001 Version 3.5 - A special DirectShow filter developed and included to iuVCR distributive as workaround some fatal bugs of nVidia WDM capture driver 1.4 - Bug fixed: in some cases sound switched off when capturing process started. - Option "Keep preview if available" removed as obsolete - The "Frame rate" box implemented into video format dialog box. 08/12/2001 Version 3.4 - Bug fixed: wrong work with some card families having a hardware overlay such as ATI, ASUS - Bug fixed: some video formats display incorrectly on "Info" tab. - Some other minor bug fixed. 08/09/2001 Version 3.3 - Help file extended - Bug fixed: Keeping sound when Preview to stopped. - Bug fixed: Override last selected channel with new frequency when /ch: command line parameter was used. 08/06/2001 Version 3.2 - Presets manager added. - Windows Scheduled Tasks integration implemented. - New command line switches: P, MUTE, NOTV, NOXBAR. - New option: "AVI compatibility index". 06/20/2001 Version 3.1 - Bug fixed: Audio compression work properly only during first capture session - Additional resolution (384x288) inserted to predefined resolutions list (3x4) 06/15/2001 Version 3.0 - Audio compression codecs available now. - Microsoft Windows Media Encoder integration added. - Some interface changes. 05/10/2001 Version 2.2 - Bug fixed: Bad audio header parameters for stereo formats. - Bug fixed: Application is not autoclosed during batch mode. - Now log combobox have a popup menu. - Number of log events increased. 05/06/2001 Version 2.1 - User interface revised: One button instead two now using. Full screen mode for preview window Keyboard shortcuts implemented. Statistic now placed on the "Info" sheet. - Some optimizations for internal algorithms make. - Some bug fixes performed. 04/18/2001 Version 2.0 - Program distributed now as shareware. - Audio Mixer recording line params stored now. - Alternative, more comfortable dialog windows for crossbar and video stream settings (old dialogs available by right mouse button click). - Preview window now may be showed during capturing stream any format. This result obtained by means of "Smart Tee" filter using and require powerful CPU (at least 500Mhz). - Preview window now have popup menu with options. - New command line switches. - Some interface changes. 03/05/2001 Version 1.2 - Bug fixed: raising exception when capture mode started after preview mode. - Bug fixed: video standard was not memorized when channels list was empty. - New option: Preview may be keep during capture, if this available by driver. - Preview window parameters remain now. - Audio PCM formats now available for selecting. - If channel number set in command line exceed 200 it will interpret as frequency. (this mode did not tested!) - Some changes into the interface. 02/04/2001 Version 1.1 - multiple device support improved. - User interface remade. - Preview now worked in overlay mode. - Channel scanning improved. - New command line switch "/F:". - Alternate locations for capturing easily now. - Statistic information about capturing extended. - COM interface for external control attached. - Some bugs fixed. 01/10/2001 Version 1.0 - First release.